Performance issues after upgrade from SLES11 SP1 to SP2 or SP3
This document (7011982) is provided subject to the disclaimer at the end of this document.
Environment
SUSE Linux Enterprise Server 11 Service Pack 2
Situation
Resolution
SUSE Linux Enterprise Server 11 SP3:
kernel-$FLAVOUR-3.0.101-0.15
cpupower-2.6.39-2.21
After updating to these package versions, available and used C-states can be shown with:
# cpupower idle-info
The desired C-State can be set with e.g.:
# cpupower idle-set -d 3
C-state no 3 gets disabled (not used by the kernel anymore) at runtime
# cpupower idle-set -e 3
will re-enable this state.
Two manpages have been added to the cpupower update as well which include more
detailed information:
cpupower-idle-info(1) and cpupower-idle-set(1)
Cause
Additional Information
SUSE Linux Enterprise Server 11 SP2:
Since SP2 is out of general support, no code fix is provided. Therefore the following boot/kernel parameter is a proper solution:
intel_idle.max_cstate=0
This might improve performance only when C-states for CPUs are disabled in the BIOS. If C states are enabled in the BIOS, you might still see performance issues. If that is the case, either disable them in the BIOS or additionally use the following kernel parameter:
processor.max_cstate=0
This disables C-states on kernel level.
Disclaimer
This Support Knowledgebase provides a valuable tool for SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.
- Document ID:7011982
- Creation Date: 19-Mar-2013
- Modified Date:10-Mar-2021
-
- SUSE Linux Enterprise Server
For questions or concerns with the SUSE Knowledgebase please contact: tidfeedback[at]suse.com