Clear cache on SUSE Manager Proxy
This document (7018416) is provided subject to the disclaimer at the end of this document.
Environment
SUSE Manager 2.1
Situation
- Work around DMZs
- Save bandwidth via RPM caching
- Alleviate a little bit of the computational load to the SUSE Manager server via XMLRPC API response caching.
In some situations (e.g. disk space problems, digest verification issues reported by zypper), it might be desired to flush the cache in the Proxy.
Resolution
spacewalk-proxy stop
rm -rf /var/cache/squid/*
squid -z -N
spacewalk-proxy start
Cause
Additional Information
All services have been refreshed.
Repository 'SLES11-SP4-Pool for x86_64' is up to date.
Retrieving repository 'SLES11-SP4-SUSE-Manager-Tools x86_64' metadata [\]
Warning: Digest verification failed for file 'updateinfo.xml.gz'
[/var/cache/zypp/raw/susemanager:sles11-sp4-suse-manager-tools-x86_64qmNNht/repodata/updateinfo.xml.gz]
expected 0fe3250dcca441ff3ec9d5935982e7e12af3690d
but got bca670744a56453e847c669b705bb7939a2c399e
Accepting packages with wrong checksums can lead to a corrupted system and in extreme cases even to a system compromise.
However if you made certain that the file with checksum 'bca6..' is secure, correct
and should be used within this operation, enter the first 4 characters of the checksum
to unblock using this file on your own risk. Empty input will discard the file.
Unblock or discard? [bca6/? shows all options] (discard):
Disclaimer
This Support Knowledgebase provides a valuable tool for SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.