![](/nbswebapp/YES.png) | HP ProLiant DL370 G6 2.93GHz Quad Core
Network Server
Fujitsu | 09 Oct 2009
130428 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 Service Pack 2 for SUSE® SLES 12 |
Other Products:
SUSE® OpenStack Cloud 7 - Admin & Control Node |
Virtual Machines (Guests OS):
NetWare 6.5 |
|
SP:
Support Pack 8 for NetWare 6.5 |
Arch:
32 |
Mode:
Paravirtualized |
Windows 2003 Server R2 |
|
SP:
Service Pack 2 for Windows 2003 |
Arch:
32 |
Mode:
Fully Virtualized |
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit http;;//www.hp.com/go/proliantlinux
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | G6 |
BIOS/uEFI: | P63 -03/04/2009 |
CPU: | 2 Intel
Xeon® Processor X5570 2.93 GHz |
RAM: | 144 GB |
Ports and Bus Types: | Serial 5 USB Ports 7 PCI Express X8 3 PCI Express X16 |
Video Adapter: | ATI
Integrated RN50 |
Host Bus Adapter: | Intel
Integrated 82801JIB ICH10
, Serial ATA (SATA) HP
Smart Array P410i Controller
, Serial SCSI (SAS) |
Hard Disk Drive: | 3 HP
DH072ABAA6 72GB SAS
, Serial SCSI (SAS) |
CD/DVD: | HLDS
DVD-ROM GDRH20N
, Serial ATA (SATA) |
Floppy Type: | NONE |
Test Kit: | System Certification Kit 6.4.0-0.16 |
Config Notes
- Maintenance update: SLES 11 SP3 Xen maintenance update 8588 and kernel update 8827 (x86-64) are required and were installed during certification testing.
- Install: System installed using an external USB DVD drive; the OS was installed from DVD using the UEFI boot loader and elilo system configuration.
- Kdump: the crash kernel reserved memory parameter in the elilo.conf file was changed from 128 to 256 (crashkernel=512M-:256M) for kdump to function correctly.
- VM Driver Pack: All FV guests were tested with PV drivers installed. The SLES 11 SP3 drivers are included with the OS. The Windows 2012 R2 drivers are available from http://download.novell.com (VMDP-WIN-2.1.exe).
- Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=10G dom0_max_vcpus=10.
- PCI Network Pass-Through: System was tested using PCI pass-through where one of the host network adapters was given to one of the SLES 11 SP3 x86-64 guests. One adapter in the embedded I350-T4 ML2 Quad Port GbE was used during this testing.
|
Referenced Bulletins
141274
Adapters and Drivers
| | | | | |
ATI
Integrated RN50 |
| Driver Type: Video Driver | Driver Name: radeon_drv.so |
| Driver Date: 25-Feb-2009 | Driver Size: 605728 |
| Checksum: 7206f6384c3ece573e2f36326d02bf0d |
|
4 HP
NetXen 375i |
| Driver Type: LAN Driver | Driver Name: netxen_nic.ko |
| Driver Date: 28-Feb-2009 | Driver Size: 115880 |
| Checksum: 9173c26f3c46efacaef057a99f7353a0 |
|
Intel
Integrated 82801JIB ICH10 |
| Driver Type: HBA Driver | Driver Name: ata_piix.ko |
| Driver Date: 28-Feb-2009 | Driver Size: 37888 |
| Checksum: f61b4d99290f0e0787976ed38fd5ba04 |
|
HP
Smart Array P410i Controller |
| Driver Type: HBA Driver | Driver Name: cciss.ko |
| Driver Date: 28-Feb-2009 | Driver Size: 99360 |
| Checksum: 8168c0181e1b586f9af4e14bf3cb8fa8 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Fujitsu
Fujitsu Technology Solutions GmbH
Mies-van-der-Rohe-Strasse 8
München
80807
GERMANY
|