| ProLiant BL460c G6 2.93GHz Six Core
Network Server
Hewlett-Packard Company | 18 May 2010
132028 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
Product Description
For more information, please visit http://www.hp.com/go/proliantlinux
Tested Configuration:
Computer Type: | Blade Module |
Mother Board Revision: | G6 |
BIOS/uEFI: | I24 - 03/30/2010 |
CPU: | 2 Intel
Xeon® Processor X5670 2.93 GHz |
RAM: | 192 GB |
Ports and Bus Types: | 3 USB Ports 2 PCI Express X8 Serial |
Video Adapter: | ATI
Integrated RN50 |
Host Bus Adapter: | HP
Smart Array P410i Controller
, Serial SCSI (SAS) |
Hard Disk Drive: | 2 HP
DG072A3315 72GB SAS 10K
, Serial SCSI (SAS) |
Floppy Type: | NONE |
Test Kit: | System Certification Kit 6.5.0-0.30 |
Config Notes
- Installation Kit: The lenovo_servers_thinksystem-sle12sp2-x86_64-1.0.iso installation kit is SUSE SolidDriver Program compliant. This installation kit must be downloaded and used to start the SLES installation. To obtain the installation kit go to: https://drivers.suse.com/lenovo/Lenovo-ThinkSystem/sle-12-sp2-x86_64/1.0/.
- Kdump (SLE12SP2): the crash kernel reserved memory parameters were increased from the default to crashkernel=167M,high crashkernel=122M,low using YaST.
- Install: System installed using an external USB DVD drive; the OS was installed from DVD using the UEFI boot loader and system configuration. Hard disk configuration: two M.2 boot drives configured as RAID 1 and two HDD configured as RAID 0.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 12 FV guest. One of the X550-T2 10GBase-T adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
ATI
Integrated RN50 |
| Driver Type: Video Driver | Driver Name: radeon_drv.so |
| Driver Date: 25-Feb-2009 | Driver Size: 605728 |
| Checksum: 7206f6384c3ece573e2f36326d02bf0d |
|
2 HP
NC532i Dual-port 10Gb Multifunction |
| Driver Type: LAN Driver | Driver Name: bnx2x.ko |
| Driver Date: 28-Feb-2009 | Driver Size: 585216 |
| Checksum: e8b22d747c8bbb64d8f02868a4244413 |
|
HP
Smart Array P410i Controller |
| Driver Type: HBA Driver | Driver Name: cciss.ko |
| Driver Date: 28-Feb-2009 | Driver Size: 98928 |
| Checksum: 03b6da33bc0731e149a4555eaeecd19d |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hewlett-Packard Company
Industry Standard Server Division
20555 SH249
Houston
, TX
77070