![](/nbswebapp/YES.png) | ProLiant BL460c G6 2.93GHz Six Core
Network Server
Lenovo | 21 May 2010
132077 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 with XEN Service Pack 3 for SUSE® SLES 12 |
Virtual Machines (Guests OS):
SUSE® LINUX Enterprise Server 10 for AMD64 & Intel64 |
|
Arch:
64 |
Mode:
Fully Virtualized |
SP:
Service Pack 3 for SLES 10 |
NetWare 6.5 |
|
SP:
Support Pack 8 for NetWare 6.5 |
Arch:
32 |
Mode:
Paravirtualized |
Windows 2003 Server R2 |
|
SP:
Service Pack 2 for Windows 2003 |
Arch:
32 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit http://www.hp.com/go/proliantlinux
Tested Configuration:
Computer Type: | Blade Module |
Mother Board Revision: | G6 |
BIOS/uEFI: | I24 - 03/30/2010 |
CPU: | 2 Intel
Xeon® Processor X5670 2.93 GHz |
RAM: | 192 GB |
Ports and Bus Types: | 3 USB Ports 2 PCI Express X8 Serial |
Video Adapter: | ATI
Integrated RN50 |
Host Bus Adapter: | HP
Smart Array P410i Controller
, Serial SCSI (SAS) |
Hard Disk Drive: | 2 HP
DG072A3315 72GB SAS 10K
, Serial SCSI (SAS) |
Floppy Type: | NONE |
Test Kit: | System Certification Kit 6.5.0-0.30 |
Config Notes
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 12 FV guest. One of the integrated Ethernet Connection X722 for 1GbE adapters was used in this testing.
- VM Driver Pack: All guests were tested with PV drivers installed. The SLES drivers are included with the OS. The Windows Server 2016 drivers are available from http://download.suse.com (VMDP-WIN-2.4.exe).
- Xen Hypervisor: the hypervisor was booted with and requires the following additional load parameters: dom0_mem=8G dom0_max_vcpus=4 (the parameters are required, the specific values can be changed).
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Disk configuration: HDD two disks configured as RAID 0 and M.2 boot device with two SSDs configured as a RAID 1 device.
|
Referenced Bulletins
146200
Adapters and Drivers
| | | | | |
ATI
Integrated RN50 |
| Driver Type: Video Driver | Driver Name: radeon_drv.so |
| Driver Date: 22-Apr-2008 | Driver Size: 304640 |
| Checksum: 4532b0e93d2ab5a98ae54beefd43e51d |
|
2 HP
NC532i Dual-port 10Gb Multifunction |
| Driver Type: LAN Driver | Driver Name: bnx2x.ko |
| Driver Date: 28-Apr-2010 | Driver Size: 788472 |
| Checksum: 41d0d17300f321ed463259c912466d25 |
|
HP
Smart Array P410i Controller |
| Driver Type: HBA Driver | Driver Name: cciss.ko |
| Driver Date: 05-Sep-2009 | Driver Size: 105096 |
| Checksum: a0a7d8772a21aee9b587f4be10f068b9 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Lenovo
For support regarding this specific configuration, please visit:
support.lenovo.com
|