 | CH225 V3
Network Server
Hewlett-Packard Company | 25 May 2016
144598 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
Other Products:
SUSE® Linux Enterprise Workstation Extension |
Product Description
http://e.huawei.com/en/products/cloud-computing-dc/servers/e-series/ch225-v3-node
Tested Configuration:
Computer Type: | Blade Module |
Mother Board Revision: | V100R003 |
BIOS/uEFI: | UEFI-Legacy: 3.18 (04/05/2016) |
CPU: | 2 Intel
Xeon® Processor E5-2699 v4 2.20 GHz |
RAM: | 32 GB |
Ports and Bus Types: | 2 PCI Express X1 3 PCI Express X8 |
Video Adapter: | Silicon Motion, Inc.
SM750 |
Host Bus Adapter: | LSI Logic
LSISAS 2308 SAS Controller
, Serial SCSI (SAS) |
Hard Disk Drive: | Seagate®
ST9300603SS Savvio® 10K.3 6-Gb/s 300-GB
, Serial SCSI (SAS) |
Test Kit: | System Certification Kit 7.5.0-20.4 |
Config Notes
- Power management: Hibernation/Suspend to Disk/ACPI S4 is NOT supported on this system.
- Power management: System/Processor does NOT support fan thermal scaling.
- Graphics: Video driver used in testing was downloaded from http://www.hp.com/support/workstations. Video driver is not SolidDriver-compliant and requires installation of kernel source and development tools.
- Kdump: the crash kernel reserved memory parameter was changed to 256 (crashkernel=512M-:256M) for kdump to function correctly.
- System was tested with an Intel I210-T1 added as a second network adapter. The standard system configuration does not include the I210-T1 adapter.
|
Referenced Bulletins
142876
Adapters and Drivers
| | | | | |
Silicon Motion, Inc.
SM750 |
| Driver Type: Video Driver | Driver Name: libfb.so |
| Driver Date: 26-May-2015 | Driver Size: 138752 |
| Checksum: ed7cf2d9c60c06fca06019e821c4b4eb |
| Driver Version: 1.0.0 |
|
Broadcom®
BCM5719 X4 PCI Express® Quad-Port Gigabit Ethernet Controller |
| Driver Type: LAN Driver | Driver Name: tg3.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 249143 |
| Checksum: ceed4fcec3c2fa76027c456bc8e570d4 |
| Driver Version: 3.137 |
|
LSI Logic
LSISAS 2308 SAS Controller |
| Driver Type: HBA Driver | Driver Name: mpt2sas.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 282159 |
| Checksum: 099b557ca954bbc129f1dfec43e27899 |
| Driver Version: 20.100.00.00 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hewlett-Packard Company
Workstation Global Business Unit
Fort Collins
, CO
80528
Website: http://www.hp.com
|