| SGI® InfiniteStorage™ Server C1104-GP6
Network Server
New H3C Technologies Co., Ltd. | 03 Jun 2016
144648 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 Service Pack 3 for SUSE® SLES 12 |
Virtual Machines (Guests OS):
3
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SLES 11 |
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
The SGI® InfiniteStorage™ Server (ISS) C1104-GP6 Server is a reliable, 1U standard depth, I/O server. The C1104-GP6 is an ideal Lustre OSS and MDS server, offering a cost effective building block for storage and I/O intensive solutions, as well as serving as a utility server for other roles
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | 1.02B |
BIOS/uEFI: | UEFI: 2.0 (12/17/2015) |
CPU: | Intel
Xeon® Processor E5-2699 v4 2.20 GHz |
RAM: | 128 GB |
Ports and Bus Types: | Serial 4 USB Ports PCI Express X8 2 PCI Express X16 |
Video Adapter: | ASPEED
AST2400 |
Host Bus Adapter: | Intel
C612 Chipset (DH82029 PCH)
, Serial ATA (SATA) LSI Logic
LSISAS 2308 SAS Controller
, Serial SCSI (SAS) Intel
Non-Volatile memory controller (NVMe)
, NVMe |
Hard Disk Drive: | Intel
SSD DC P3700 Series
, NVMe 2 Hitachi GST
HUS156030VLS600
, Serial SCSI (SAS) Seagate®
ST8000NM0045-1RL
, Serial ATA (SATA) Supermicro Computer
SSD-DM016-PHI
, Serial ATA (SATA) Seagate®
ST1000NM0033
, Serial ATA (SATA) |
Test Kit: | System Certification Kit 7.5.0-20.4 |
Config Notes
- Install: OS installed via USB CD/DVD drive.
- Kdump (SLE12SP3): the crash kernel reserved memory parameters were increased from the default to crashkernel=512M,high crashkernel=256M,low using YaST.
|
Adapters and Drivers
| | | | | |
ASPEED
AST2400 |
| Driver Type: Video Driver | Driver Name: swrast_dri.so |
| Driver Date: 12-May-2015 | Driver Size: 14588208 |
| Checksum: e32ce0677419b22ed04c0a096fd98546 |
|
| Driver Type: Video Driver | Driver Name: ast_drv.so |
| Driver Date: 17-Jun-2015 | Driver Size: 134960 |
| Checksum: 01ba3e8b5ba7aff90b4e5d72d1a05efe |
| Driver Version: 1.0.1 |
|
Intel
Ethernet Controller I350-AM2 (Dual Port) |
| Driver Type: LAN Driver | Driver Name: igb.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 334639 |
| Checksum: 9d13a78672ff61d57ef1b462ada1ae55 |
| Driver Version: 5.2.15-k |
|
Intel
C612 Chipset (DH82029 PCH) |
| Driver Type: HBA Driver | Driver Name: ahci.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 58775 |
| Checksum: 7a0c250f60b9ac6b9684c7be9f36b03e |
| Driver Version: 3.0 |
|
LSI Logic
LSISAS 2308 SAS Controller |
| Driver Type: HBA Driver | Driver Name: mpt2sas.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 282159 |
| Checksum: 099b557ca954bbc129f1dfec43e27899 |
| Driver Version: 20.100.00.00 |
|
Intel
Non-Volatile memory controller (NVMe) |
| Driver Type: HBA Driver | Driver Name: nvme.ko |
| Driver Date: 24-Jun-2015 | Driver Size: 113407 |
| Checksum: 01c699cf90507a6666cf0ed143a7dea4 |
| Driver Version: 0.9 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
New H3C Technologies Co., Ltd.
466 Changhe Road
Binjiang District
Hangzhou, Zhejiang Province
CHINA
|