|
 | ThinkServer RD350 (70Qx/E5-2600 v4)
Network Server
Lenovo | 21 Nov 2017
146269 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 with XEN Service Pack 3 for SUSE® SLES 12 |
Virtual Machines (Guests OS):
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
Arch:
64 |
Mode:
Fully Virtualized |
SP:
Service Pack 3 for SUSE® SLES 12 |
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 3 for SUSE SLES 12 |
Arch:
64 |
Mode:
Paravirtualized |
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
64 |
Mode:
Paravirtualized |
SUSE® Linux Enterprise Server 11 for x86 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
32 |
Mode:
Fully Virtualized |
Product Description
For more information about this system, please visit www.lenovo.com.
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | Rev 1.1 |
BIOS/uEFI: | UEFI: VB3TS424 - v4.24 (03/23/2017) |
CPU: | 2 Intel
Xeon® Processor E5-2660 v4 2.00 GHz |
RAM: | Host platform: 128 GB, single max VM guest: 112 GB, multiple VM guests: 24 GB each |
Ports and Bus Types: | 4 USB Ports Serial 5 PCI Express X8 PCI Express X16 |
Video Adapter: | ASPEED
AST2400 |
Host Bus Adapter: | Lenovo
ThinkServer RAID 720i AnyRAID Adapter
, Serial SCSI (SAS) |
Hard Disk Drive: | 2 Hitachi GST
HUC109060CSS600
, Serial SCSI (SAS) |
Test Kit: | System Certification Kit 7.7.0-25.1 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Hard disk configuration: RAID 1. Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=8G dom0_max_vcpus=4.
- Kdump (SLE12SP3): the crash kernel reserved memory parameters were increased from the default to crashkernel=199M,high crashkernel=142M,low using YaST.
- PCI Network Pass-Through: System was tested using PCI pass-through where one of the host network adapters was given to one of the SLES 12 SP3 x86-64 guests. One of the integrated Ethernet Controller I210-AT adapters was used during this testing.
|
Referenced Bulletins
145939
Adapters and Drivers
| | | | | |
ASPEED
AST2400 |
| Driver Type: Video Driver | Driver Name: ast.ko |
| Driver Date: 08-Jul-2017 | Driver Size: 110615 |
| Checksum: 25a265f887c0d4cf4122d039be7edd23 |
|
| Driver Type: Video Driver | Driver Name: drm.ko |
| Driver Date: 08-Jul-2017 | Driver Size: 629239 |
| Checksum: 11dc012a6820631069019c6571691ad7 |
|
| Driver Type: Video Driver | Driver Name: ast_drv.so |
| Driver Date: 14-Oct-2016 | Driver Size: 114288 |
| Checksum: d8354d50377cbbdc635b0a299a0f5d38 |
| Driver Version: 1.1.5 |
|
Lenovo
ThinkServer RAID 720i AnyRAID Adapter |
| Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| Driver Date: 08-Jul-2017 | Driver Size: 236751 |
| Checksum: c96d2df516f3a67f3960bb982a2a0b3d |
| Driver Version: 07.701.17.00-rc1 |
|
2 Intel
Ethernet Controller I210-AT |
| Driver Type: LAN Driver | Driver Name: igb.ko |
| Driver Date: 08-Jul-2017 | Driver Size: 356223 |
| Checksum: a9ef182572c767dbda6b901513d6c487 |
| Driver Version: 5.4.0-k |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Lenovo
For support regarding this specific configuration, please visit:
support.lenovo.com
|