 | ClearPath Forward Fabric 4.1
Network Server
Oracle America Inc. | 31 Aug 2018
147038 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 with XEN Service Pack 1 for SUSE® SLES 11 |
Virtual Machines (Guests OS):
3
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
The ClearPath Forward™ fabric delivers the cost effective power, scalability, predictable performance, and security to support mission-critical applications running on SUSE Linux operating systems. ClearPath Forward fabric blends industry standard fabric technology with decades of mission critical expertise to deliver mission critical architecture on Intel X86. The ClearPath Forward™ Release 4.1 (PEPP) 2-Socket platform is applicable to all Unisys ClearPath Forward models, including ClearPath Forward, ClearPath Forward Libra 4380, 4390, 6380, 6390, 8380, & 8390 as well as ClearPath Forward Dorado 4350, 4370, 4380, 4390, 6380, 6390, 8380, 8390, and ES3000 3560R G5.
Tested Configuration:
Computer Type: | Virtual Machine |
Mother Board Revision: | Unisys 0599V5 Rev. A02 |
BIOS/uEFI: | UEFI: 1.23 (12/15/2009) |
CPU: | 2 Intel
Xeon® Processor E5-2698 v4 2.20 GHz |
RAM: | Host Platform: 384 GB, 64-bit VM Guests: 124 GB, Single Max VM 64-bit Guest Tested Memory: 372 GB |
Ports and Bus Types: | 6 PCI Express X8 4 USB Ports |
Video Adapter: | Unisys
Virtual Video Controller |
Host Bus Adapter: | Unisys
Virtual SCSI storage controller
, Serial SCSI (SAS) |
Hard Disk Drive: | Unisys
Virtual Hard Disk Drive
, Serial SCSI (SAS) |
Test Kit: | System Certification Kit 8.1.0-83.2 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Tested as a 2-node scalable partition with 8 Compute Books. Hard disk configuration: separate RAID 0. Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=12G dom0_max_vcpus=8.
- Kdump: the crash kernel reserved memory parameters were increased from the default to "crashkernel=210M,high crashkernel=162M,low" using YaST.
- VM Driver Pack: All guests were tested with PV drivers installed. The SLES drivers are included with the OS. The Windows 2012 R2 drivers are available from http://download.suse.com (VMDP-WIN-2.3.exe).
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to the SLES 12 FV guest. One of the Intel X540 ML2 Dual Port 10GbaseT adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
Unisys
Virtual Video Controller |
| Driver Type: Video Driver | Driver Name: fbdev_drv.so |
| Driver Date: 21-Nov-2017 | Driver Size: 23688 |
|
| Driver Version: 0.4.1 |
|
Unisys
Virtual SCSI storage controller |
| Driver Type: HBA Driver | Driver Name: virthbamod.ko |
| Driver Date: 21-Nov-2017 | Driver Size: 64248 |
|
| Driver Version: 4.5.4.30657 |
|
Unisys
Virtual Ethernet Controller |
| Driver Type: LAN Driver | Driver Name: virtnicmod.ko |
| Driver Date: 21-Nov-2017 | Driver Size: 109336 |
|
| Driver Version: 4.5.4.30657 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Oracle America Inc.
500 Oracle Parkway
Redwood Shores
, CA
94065
Website: www.Oracle.com
|