| H3C UniServer R2900 G3
Network Server
IEIT SYSTEMS Co., Ltd. | 29 May 2019
148143 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 Service Pack 5 for SUSE® SLES 12 |
Product Description
H3C UniServer R2900 G3
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | 0302A3FR |
BIOS/uEFI: | UEFI: 2.00.27 (04/30/2019) |
CPU: | 2 Intel
Xeon® Gold 6230 Processor 2.10 GHz |
RAM: | 128 GB |
Ports and Bus Types: | 2 PCI Express X8 5 USB Ports |
Video Adapter: | ASPEED
AST2500 |
Host Bus Adapter: | Intel
C621 Chipset
, Serial ATA (SATA) |
Hard Disk Drive: | Seagate®
Exos 7E8 6TB 512e SATA (ST6000NM0115)
, Serial ATA (SATA) |
Test Kit: | System Certification Kit 8.2.0-15.5 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration.
- System support: Please note that for full support on the listed OS release a special SUSE support contract is necessary.
|
Referenced Bulletins
150177
Adapters and Drivers
| | | | | |
ASPEED
AST2500 |
| Driver Type: Video Driver | Driver Name: ast.ko |
| Driver Date: 31-May-2018 | Driver Size: 130632 |
| Checksum: 2b1d7c8b92a90ff3b3c5fce07dcc9ffe |
|
Intel
Ethernet Connection X722 (Quad-Port) for 1GbE |
| Driver Type: LAN Driver | Driver Name: i40e.ko |
| Driver Date: 31-May-2018 | Driver Size: 672856 |
| Checksum: ed0ba4d00cc73bffeeda57b9f3ec8b73 |
| Driver Version: 2.1.14-k |
|
Intel
C621 Chipset |
| Driver Type: HBA Driver | Driver Name: ahci.ko |
| Driver Date: 31-May-2018 | Driver Size: 79168 |
| Checksum: 4f7c7f0d69f4ac743ca67d4e22b5c8ef |
| Driver Version: 3.0 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IEIT SYSTEMS Co., Ltd.
East side of Floor 9, No. 801, Caoshanling South Road, High-tech Zone, Jinan City, Shandong Province, PRC
Jinan
250101
CHINA
Website: https://www.ieisystem.com
|