| E900 G4
Network Server
VMware, Inc. | 10 Dec 2019
148957 |
SUSE YES Certified for the following products:
Product Description
4-Way Graphics for Full-Force Performance.
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | Rev 2.00 |
BIOS/uEFI: | UEFI: 5503 (04/11/2019) |
CPU: | 2 Intel
Xeon® Gold 6248 Processor 2.50 GHz |
RAM: | 128 GB |
Ports and Bus Types: | 11 USB Ports 2 PCI Express X8 5 PCI Express X16 USB-C |
Video Adapter: | ASPEED
AST2500 |
Host Bus Adapter: | Intel
C621 Chipset
, Serial ATA (SATA) |
Hard Disk Drive: | TSST
MG04ACA100N - 3.5-inch Enterprise Performance SATA HDD 1TB
, Serial ATA (SATA) |
CD/DVD: | Asus
GHD2N
, Serial ATA (SATA) |
Test Kit: | System Certification Kit 8.3.0-27.1 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Hard disk configuration: RAID 1. Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=8G dom0_max_vcpus=4.
- Kdump (SLE12SP3): the crash kernel reserved memory parameters were increased from the default to crashkernel=199M,high crashkernel=142M,low using YaST.
- PCI Network Pass-Through: System was tested using PCI pass-through where one of the host network adapters was given to one of the SLES 12 SP3 x86-64 guests. One of the integrated Ethernet Controller I210-AT adapters was used during this testing.
|
Referenced Bulletins
145939
Adapters and Drivers
| | | | | |
ASPEED
AST2500 |
| Driver Type: Video Driver | Driver Name: ast.ko |
| Driver Date: 15-May-2019 | Driver Size: 130840 |
| Checksum: 91f3d373f3311797e9becd7cb5292262 |
|
2 Intel
Ethernet Controller I210-AT |
| Driver Type: LAN Driver | Driver Name: igb.ko |
| Driver Date: 15-May-2019 | Driver Size: 496992 |
| Checksum: 1bbdfabf69501dd0a3c43a5e18035bd4 |
| Driver Version: 5.4.0-k |
|
Intel
C621 Chipset |
| Driver Type: HBA Driver | Driver Name: ahci.ko |
| Driver Date: 14-May-2019 | Driver Size: 81288 |
| Checksum: cda6f840da0973af652a5672382ed473 |
| Driver Version: 3.0 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
VMware, Inc.
3401 Hillview Ave
Palo Alto
, CA
94304
Voice: 1-650-427-5000
Toll Free: 1-877-486-9273
Fax: 650-427-5001
Website: www.vmware.com
|