![](/nbswebapp/YES.png) | ThinkSystem SR655 (7Z01, EPYC 7002)
Network Server
IBM | 21 Jul 2020
149473 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 with XEN Service Pack 3 for SUSE® SLES 11 |
Virtual Machines (Guests OS):
Windows Server 2019 |
|
Arch:
64 |
Mode:
Fully Virtualized |
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 2 for SUSE SLES 15 |
Arch:
64 |
Mode:
Paravirtualized |
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 5 for SUSE SLES 12 |
Arch:
64 |
Mode:
Paravirtualized |
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 5 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
Arch:
64 |
Mode:
Fully Virtualized |
SP:
Service Pack 2 for SUSE® SLES 15 |
Product Description
For more information about this system, please visit www.lenovo.com.
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | SB27A42857 |
BIOS/uEFI: | UEFI: CFE107O v2.00 (12/28/2019) |
CPU: | AMD
EPYC™ 7742 2.25 GHz |
RAM: | Host: 128 GB, mutiple VMs: 20 GB each, single max VM: 100 GB |
Ports and Bus Types: | 4 USB Ports 3 PCI Express X16 |
Video Adapter: | ASPEED
AST2500 |
Host Bus Adapter: | Lenovo
ThinkSystem RAID 930-8i 2GB Flash PCIe 12GB Adapter
, Serial SCSI (SAS) |
Hard Disk Drive: | Seagate®
Enterprise Performance 10K 1.8TB SAS 512E HDD - ST1800MM0018
, Serial SCSI (SAS) |
Test Kit: | System Certification Kit 8.5.0-29.1 |
Config Notes
- Install: PXE Boot, OS Installed via network.
- Hard Disk Configuration: RAID 1.
- PCI Network Pass-Through: System was tested using PCI pass-through where the network adapter was given to the SLES 11 SP3 x86-64 guest. One of the embedded Broadcom® Integrated BCM5709C Dual-Port 10/100/1000BASE-T TOE PCI Express® Ethernet Controller adapters was used in this testing.
|
Referenced Bulletins
139642
Adapters and Drivers
| | | | | |
ASPEED
AST2500 |
| Driver Type: Video Driver | Driver Name: ast.ko |
| Driver Date: 06-Jun-2020 | Driver Size: 115632 |
| Checksum: f1fc1a718c1def157bd5b84ad0d9dbae |
|
Broadcom®
BCM5719 X4 PCI Express® Quad-Port Gigabit Ethernet Controller |
| Driver Type: LAN Driver | Driver Name: tg3.ko |
| Driver Date: 06-Jun-2020 | Driver Size: 327944 |
| Checksum: 66da90edfc8f437ccc9dd3572911dc80 |
| Driver Version: 3.137 |
|
Lenovo
ThinkSystem RAID 930-8i 2GB Flash PCIe 12GB Adapter |
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IBM
For support regarding this specific configuration, please visit:
www.ibm.com
|