| ThinkSystem SR665 (7D2W, EPYC 7003)
Network Server
IEIT SYSTEMS Co., Ltd. | 20 Jun 2023
152221 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 Service Pack 4 for SUSE® SLES 15 |
Virtual Machines (Guests OS):
2
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 5 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
2
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
Arch:
64 |
Mode:
Paravirtualized |
SP:
Service Pack 5 for SUSE® SLES 15 |
Product Description
For more information, please visit www.lenovo.com.
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | 03 |
BIOS/uEFI: | UEFI: D8E127F-2.50 (09/20/2022) |
CPU: | 2 AMD
EPYC™ 7763 2.45 GHz |
RAM: | 1 TB |
Video Adapter: | Matrox Graphics Inc.
G200 SE A (PCI) |
Host Bus Adapter: | Lenovo
ThinkSystem RAID 530-8i PCIe 12Gb Adapter |
Hard Disk Drive: | Lenovo
ThinkSystem 2.5-inch PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD |
Test Kit: | System Certification Kit 8.8.0-150400.74.1 |
Config Notes
- Install: PXE boot, OS installed via network.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 15 FV guest. One of the 361T adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
Intel
Ethernet Network Adapter X710-T4L (Quad Port) |
| Driver Type: LAN Driver | Driver Name: i40e.ko.zst |
| Driver Date: 06-Apr-2023 | Driver Size: 301024 |
| Checksum: 36c8d1550c23b0bb0fdb2dc5b6c6419f |
|
Lenovo
ThinkSystem RAID 530-8i PCIe 12Gb Adapter |
| Driver Type: HBA Driver | Driver Name: megaraid_sas.ko.zst |
| Driver Date: 06-Apr-2023 | Driver Size: 120683 |
| Checksum: 51d1c66ea16d4297953f4b58806e2ed0 |
| Driver Version: 07.719.03.00-rc1 |
|
Matrox Graphics Inc.
G200 SE A (PCI) |
| Driver Type: Video Driver | Driver Name: mgag200.ko.zst |
| Driver Date: 06-Apr-2023 | Driver Size: 42073 |
| Checksum: 5cd76a2c28fd22f7179aaf39f33fb024 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IEIT SYSTEMS Co., Ltd.
East side of Floor 9, No. 801, Caoshanling South Road, High-tech Zone, Jinan City, Shandong Province, PRC
Jinan
250101
CHINA
Website: https://www.ieisystem.com
|