Upstream information
Description
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.SUSE information
Overall state of this security issue: Does not affect SUSE products
This issue is currently rated as having moderate severity.
National Vulnerability Database | |
---|---|
Base Score | 3.5 |
Vector | AV:N/AC:M/Au:S/C:P/I:N/A:N |
Access Vector | Network |
Access Complexity | Medium |
Authentication | Single |
Confidentiality Impact | Partial |
Integrity Impact | None |
Availability Impact | None |
National Vulnerability Database | |
---|---|
Base Score | 5.3 |
Vector | CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N |
Attack Vector | Network |
Attack Complexity | High |
Privileges Required | Low |
User Interaction | None |
Scope | Unchanged |
Confidentiality Impact | High |
Integrity Impact | None |
Availability Impact | None |
CVSSv3 Version | 3 |
SUSE Security Advisories:
- TID7022706, published Sa 19. Mai 14:07:09 CEST 2018
SUSE Timeline for this CVE
CVE page created: Thu Mar 8 01:25:57 2018CVE page last modified: Wed Mar 26 11:43:07 2025